Aratas G5Q-1 DC12 (C) relay reference

The Aratas G5Q-1 DC12 (C) is a through-hole PCB power relay with a 12 VDC coil and one changeover contact (SPDT, Form C). Check the load on each throw before approving the part. At 250 VAC with a resistive load, the standard G5Q-1 is rated for 5 A on the normally open (NO) contact and 3 A on the normally closed (NC) contact. Manufacturer contact ratings, p. 3

Ordering code and coil

ItemManufacturer data
Complete ordering referenceG5Q-1 DC12 (C), as listed in Aratas’s model database
Contact and enclosureOne changeover contact. Single-side stable (monostable), flux-protected enclosure.
Rated coil voltage12 VDC
Coil current and resistance33.3 mA and 360 Ω, each ±10% at a coil temperature of 23 °C
Rated coil powerApproximately 400 mW
Body envelope (L × W × H)20.3 × 10.3 × 15.8 mm maximum
Ambient operating range−40 to +105 °C, without icing or condensation

Use the complete code when requesting a quote. If your approved BOM or package label includes an ordering or packing designation, include it in the request. Confirm the offered part against that label before ordering. Exact model entry · Model legend and coil data, pp. 1–3 · Operating environment, p. 5 · Dimensions, p. 9

Resistive switching and electrical life

Use the rating for the contact that switches the load. The table below pairs each resistive load with the manufacturer’s minimum electrical endurance for the standard G5Q-1.

ContactResistive loadMinimum operations
NO10 A at 125 VAC50,000
NO3 A at 125 VAC200,000
NO5 A at 250 VAC50,000
NO3 A at 250 VAC100,000
NO5 A at 30 VDC100,000
NC3 A at 125 VAC200,000
NC3 A at 250 VAC100,000
NC3 A at 30 VDC100,000

The manufacturer specifies a 1 s on / 3 s off cycle for the 10 A, 125 VAC NO test and a 1 s on / 1 s off cycle for the listed 30 VDC tests. Read the endurance and approval tables for the conditions that apply to your board. For motors, solenoids or capacitive loads, confirm the actual turn-on peak and opening current and check the applicable load-specific rating. Contact ratings and endurance, pp. 3–4 · Approval test conditions, p. 10

PCB footprint and bottom view

Use the G5Q-1 SPDT drawing on page 9. Aratas shows both the terminal arrangement and PCB mounting holes from the underside, looking toward the solder pins. The layout calls for five holes, each Ø1.3 ± 0.1 mm. The relay coil is non-polarized.

Compare the pin positions and body clearance with your board. If the PCB library displays the footprint from the component side, account for the opposite viewing direction. Use the original circuit diagram to match the coil, COM, NO and NC terminals to the board connections. Original footprint and bottom-view wiring drawing, p. 9

Ordering questions

Does 12 VDC describe the switched load?

12 VDC is the nominal voltage applied to the coil. The voltage across the contacts depends on the load circuit. Check the AC or DC row in the contact table and use the specified operating conditions.

What if my BOM calls for a sealed enclosure?

Ask procurement to quote the complete approved sealed variant from the ordering table. The G5Q-1 DC12 (C) has a flux-protected enclosure. Confirm the permitted soldering and cleaning process against the manufacturer’s instructions before assembly. Enclosure variants and ordering table, pp. 1–2 · PCB relay handling precautions

Request a quote for the exact part

Include Aratas G5Q-1 DC12 (C), required quantity, delivery destination and target date. Add any required packing format, lot or date-code limits and documents. For an existing board, supply the BOM revision and any approved alternate restrictions. Ask 5Chips to check availability for that requirement. PCB relay sourcing guide · Aratas G5Q product documentation

Send Inquiry

Tell us what you need