PCB relay sourcing for new designs and replacements
For an approved PCB relay, send the manufacturer and complete part number from the BOM. For a new design or a replacement, describe the load the contacts will switch, the supply that drives the coil and the space available on the board. Those three checks help narrow the choice of electromechanical power or signal relay.
Start with the complete order code
Copy the entire order code from the approved BOM, packaging label or manufacturer’s ordering table. Keep every suffix. Compare the contact form, coil option, enclosure and packaging against the exact row or code breakdown for that series. If you have only the case marking, share photos of the marking and terminals together with the board revision or package label. Mark any missing portion of the order code for confirmation. The full MPN and suffix guide explains what to carry over into the purchasing record.
Describe what the contacts will switch
Give the switched voltage and whether it is AC or DC. Specify the pole count and contact form, such as normally open (NO), normally closed (NC) or changeover. For a changeover relay, identify which load connects to each throw. Record steady current, turn-on peak and duration where applicable, and current at opening. Give the expected switching frequency and target service life.
| Load on the contact | What to include with the request |
|---|---|
| Resistive load, such as a heater | Operating voltage, current at the operating condition and expected switching rate. Include cold-start current if it differs. |
| Motor or solenoid | Motor starting current or solenoid pull-in current, operating current, and the current the contacts must interrupt. Note any existing suppression on the load. |
| Capacitive input, such as some power supplies or LED drivers | Inrush peak and duration at turn-on, steady current and how frequently it is switched. Use measurements from the actual circuit when available. |
| Low-level signal | Minimum voltage and current seen by the contact, signal type and any allowable contact resistance. Check the manufacturer’s minimum-load guidance for the contact option. |
Compare the relay’s switching rating and electrical life at the actual voltage, load type and duty. Use the DC rating for a DC circuit. Where a datasheet gives a continuous carry rating, apply it to the closed-contact condition it describes. Panasonic Industry application cautions · ARATAS application guide
Match the coil to the drive circuit
Record nominal coil voltage, AC or DC, and frequency for an AC coil. Give the voltage available at the coil under operating conditions and the current the driver can supply. Compare the rated coil current or power, operate and release limits, and allowable coil voltage at the intended temperature. For a latching relay, include the required set and reset drive. If a DC relay has built-in suppression, check the polarity and confirm how release timing affects the circuit. See Panasonic Industry relay terminology for the rating and operate/release terms.
Check the PCB footprint before approving an alternate
Use the manufacturer’s outline and terminal drawings for the exact variant. Confirm through-hole or surface mounting, pin count, pin spacing, hole or pad dimensions, and available body height. Record whether the drawing is a top or bottom view. Map each coil pin, common (COM), NO and NC terminal to its board connection. Check the enclosure, board temperature and soldering or cleaning process. Where the application specifies insulation or approvals, check the exact variant and the required conditions.
When an alternate is offered, ask for its full order code, datasheet and a list of the differences. Have engineering review the load rating, electrical life, drive circuit and PCB fit before approving it. If a sample is required, check it on the intended board under the expected load and operating conditions. ARATAS guide to coils, contacts, terminals and enclosures
Prepare the request
Send the complete MPN or the selection inputs above, the board or BOM revision, the quantity you need and the target delivery date. State whether the original part is required or engineering can review an alternate. Include any packing, date code, lot or supporting document requirements. For multiple line items, use the BOM RFQ template and attach the load or footprint notes to the relevant lines.